Research Article

Flow Pattern Analysis and Performance Improvement of Regenerative Flow Pump Using Blade Geometry Modification

Table 5

Results of numerical study at design flow coefficient.

AnglesEfficiencyΨ (head coefficient)

Symmetric angle blades29.970.412
39.950.737
42.520.963
42.421.035
44.701.160
43.661.203
41.011.044

Nonsymmetric angle blades ()33.070.422
39.100.733
41.970.981
42.421.035
42.951.069
40.710.947
37.960.759