Research Article
Removal of Tricyclazole and Total Organic Carbon in Real Pesticide Wastewater by Electro-Fenton
Table 3
ANOVA results for the TC and TOC removal from RPW using EF process.
| Source | DF | Adj SS | Adj MS | F-value | value |
| TC removal | | | | | | Model | 9 | 3,126.26 | 347.36 | 69.43 | ≤0.001 | X1 | 1 | 4.71 | 4.71 | 0.94 | 0.355 | X2 | 1 | 1,263.95 | 1,263.95 | 252.65 | ≤0.001 | X3 | 1 | 457.25 | 457.25 | 91.40 | ≤0.001 | | 1 | 441.80 | 441.80 | 88.31 | ≤0.001 | | 1 | 657.55 | 657.55 | 131.44 | ≤0.001 | | 1 | 270.79 | 270.79 | 54.13 | ≤0.001 | X1X2 | 1 | 77.25 | 77.25 | 15.44 | 0.003 | X1X3 | 1 | 37.58 | 37.58 | 751 | 0.021 | X2X3 | 1 | 130.73 | 130.73 | 26.13 | ≤0.001 | Residual error | 10 | 50.03 | 5.00 | | | Pure error | 5 | 1.90 | 0.38 | | | Total | 19 | 3,176.29 | | | |
| TOC reduction | | | | | | Model | 9 | 5,247.22 | 583.02 | 49.69 | ≤0.001 | X1 | 1 | 69.20 | 69.20 | 5.90 | 0.036 | X2 | 1 | 870.03 | 870.03 | 74.15 | ≤0.001 | X3 | 1 | 2,427.60 | 2,427.60 | 206.91 | ≤0.001 | | 1 | 347.73 | 347.73 | 29.64 | ≤0.001 | | 1 | 1,216.69 | 1,216.69 | 103.60 | ≤0.001 | | 1 | 440.85 | 440.85 | 37.57 | ≤0.001 | X1X2 | 1 | 103.54 | 103.54 | 8.82 | 0.014 | X1X3 | 1 | 49.10 | 49.10 | 4.19 | 0.068 | X2X3 | 1 | 12.25 | 12.25 | 1.04 | 0.331 | Residual error | 10 | 117.33 | 11.73 | | | Pure error | 5 | 8.02 | 1.60 | | | Total | 19 | 5,364.55 | | | |
|
|
R2TC = 0.9842, R2TC_adj = 0.9701, R2TOC = 0.9781, and R2TOC_adj = 0.9584.
|