Abstract

In this study, electro-Fenton (EF) was employed for the removal of tricyclazole (TC) and total organic carbon (TOC) in real pesticide wastewater (RPW). The central composite design (CCD) with three parameters, that is, current density, Fe2+ concentration, and electrolysis time, has been conducted to predict the TOC and TC removal efficiency. The high correlation of the quadratic models of 0.9842 and 0.9781 for TC and TOC removal, respectively, indicates the significance of the models. The obtained results revealed that the high-efficiency removal of both TC and TOC in RPW. Approximately 99.6% of TC was decomposed under the optimum conditions of a current density of 2.2 mA/cm2 and an Fe2+ concentration of 0.2 mM during 188 min with an operating cost of 121.392 $/kg TC or ∼2.692 $/m3, while 84.2% TOC was eliminated at a current density of 2.2 mA/cm2 and an Fe2+ concentration of 0.2 mM during 217 min with an operating cost of 3.019 $/kg TOC or 3.916 $/m3. Acute toxicity tests at optimal condition revealed moderate exhibition toxicity of treated wastewater against Daphnia magna with LC50 values of 3.12%, 2.05%, 1.84%, and 1.36% at 24 h, 48 h, 72 h, and 96 h, respectively. The removal of TC and TOC followed pseudo-first-order kinetic with an R2 of ∼0.993 and 0.923, respectively.

1. Introduction

Agriculture is critical to the economies of Vietnam, in which export-oriented agricultural production is a significant source of foreign exchange earnings. The agricultural sector provides approximately 14.85% of the gross national product with over 18.8 million Vietnamese in 2019 [1]. However, the vast number of pesticides produced to prevent pests or diseases on crops resulting in threats to the environment and human health [2]. Extensive studies have reported that pesticides originating from agriculture factories are characterized by a high chemical oxygen demand (COD), total suspended solids (TSS), and toxicity. In particular, pesticide application to rice paddies has been detected in surface water, groundwater, and soil [3]. These kinds of pesticides also stand out in high production and worldwide distribution; tricyclazole (TC) is a unique fungicide among the most widely used pesticides for control of Pyricularia oryzae in rice fields [4, 5]. Duy et al. [6] stated that TC was moderately toxic to tropical freshwater Daphnia species (48 h LC50, 32.68 mg/L). Werner et al. [7] also stated that TC could display human mutagenic and carcinogenic [8]. Therefore, it is necessary to use appropriate techniques to remove these pollutants to preserve the environment from contaminated water. Biological processes are quite economical for the treatment of wastewaters. Wu et al. [8] had isolated Sphingomonas sp. NJUST37 from activated sludge and successfully applied to degrade over 90% tricyclazole in pilot-scale powdered activated carbon treatment tank after 81 days. However, the COD is still high around 160 mg/L, and further treatment time has insignificant effect on the removal efficiency. Moreover, biological methods have proven ineffective in removing refractory or nonbiodegradable compounds [9]. For instance, biological treatment processes have not successfully removed pesticide wastewater [10]. Alternatively, physicochemical techniques, that is, coagulation, adsorption, nanofiltration, and so on, are also used to treat wastewater; Azarkan et al. [11] had collected four clays with different characteristics from various locations in northern Morocco to adsorb 5 mg/L TC from solution; the TC mitigation obeyed pseudo-second-order kinetic model with R2 values ≥ 0.95. However, the TC removal efficiency only reached from 0.27 to 28.59% for the clays. While Kiso et al. [12] indicated that 79.8% of TC were removed using nanomembrane; the authors also stated that three other nanomembranes were negligible on the rejection of TC. Even though these methods have some applications in TC removal, these techniques transfer only the pollution from one phase to another, requiring further treatment [9, 13]. Therefore, it is essential to develop more effective treatment methods to eradicate the contaminants.

For instance, advanced oxidation processes (AOPs) are proven to be the most effective techniques for the degradation of a wide range of pollutants in aqueous solutions such as pharmaceutical [14, 15], pesticide [6], dyeing, and textile [16, 17]. The process is characterized by their ability to generate hydroxyl radical (OH) and other reactive oxygen species. One of the most important chemical reactions in the advanced oxidation process is Fenton (Fe2+/H2O2) and Fenton-like systems. The Fenton reaction was the first described by H. J. H. Fenton in 1894 [18] with chemical mechanism according to the following equation:

The Fenton reaction consists of reducing H2O2 until hydroxyl radicals and hydroxide caused by oxidation of Fe2+ to Fe3+.

However, this method has drawbacks related to the wastage of oxidants (iron ions or H2O2) and the formation of excess sludge [19]. The new Fenton process based on electrolysis systems has been developed and called electro-Fenton (EF) to overcome the disadvantages of homogeneous Fenton. In the EF process, H2O2 can be generated at the cathode when bubbling oxygen gas through the acidic solution, followed by reducing H2O2. The electrochemical generation of Fe2+ ions occurs through the reaction of anodic material dissolution or cathodic reduction of Fe3+ ions [18]. In this process, pollutants are destroyed by Fenton’s action reagent together with the combination of anode oxidation on the anode surface. The Fenton process and electrochemical are combined with the increasing degradability of organic compounds present in high-intensity wastes. Even several researchers have applied EF to eliminate pollutants from wastewater of dyeing and textile [20, 21], pharmaceuticals [14], coke [22], pesticides [2325], or mixed industrial wastewater [26]. Very few studies focus on the mineralization and biodegradability of tricyclazole and pollutants from real pesticide production by EF process [27].

In the present work, the degradation of TC and total organic carbon (TOC) in real pesticide production wastewater are investigated using the EF process in a batch chemical reactor. This study aims to analyze how the degradation process of TC and TOC can be affected by current density, Fe2+ dosage, and electrolysis time using a central composite design (CCD). Additionally, the degradation mechanism is investigated based on kinetics studies, the toxicity of the wastewater on Daphnia magna, and operating costs.

2. Experimental

2.1. Chemical and Real Pesticide Wastewater (RPW)

Ferrous sulfate (FeSO4), sodium hydroxide (NaOH), sodium sulfate (Na2SO4), hydrogen chloride (HCl), and sulfuric acid (H2SO4) were purchased from Xilong Scientific Corporation Ltd., China. All the chemicals were of analytical grade, and solutions were prepared with deionized water of resistivity not less than 18.2 MΩ/cm. The pesticide effluent was obtained from an agriculture production company located in Longan province, Vietnam. It was collected in an equalization tank after a sieve system. Wastewater was collected in a glass container and preserved at 4°C for treatment by EF. The effluent characteristics are as follows: initial pH of 6.6–7.2, total organic carbon (TOC) of 1,236–1,358 mg/L, tricyclazole (TC) of 23.7–25.1 mg/L, and total nitrogen (TN) of 240–272 mg/L.

2.2. Acute Toxicity Assay

After treatment, the pesticide wastewater with the optimal condition for TOC was selected to test the toxicity to D. magna.

The effluent was characterized as pH of 6.8, total organic carbon (TOC) of 204.4 mg/L, tricyclazole (TC) of 0.185 mg/L, and total nitrogen (TN) of 72.6 mg/L. D. magna obtained from MicroBioTest Inc., Belgium, was used for the test. The acute test was performed according to the OECD guideline 202 [28]. D. magna live stocks were cultured in glass containers at a density of 1 individual/10 mL of ISO medium [29]. The test organisms were daily fed a mixture of Scenedesmus sp. and Chlorella sp. The culture medium was renewed every three days and maintained at 25 ± 1°C under a 12:12 h light-dark cycle. For each test samples, a serial dilution (0.1%, 0.25%, 0.5%, 1.0%, 2%, and 5%) of PWAT plus the blank control was used. All test concentrations were prepared in triplicate and spiked with 40 mL of ISO medium in 50 mL glass beakers. Ten neonates (<24 h old) were added to each beaker. The test was run for 96 h at a stable pH and temperature 7.5 and 25 ± 1°C, respectively. The mortality of tested neonates was checked at 24 h, 48 h, 72 h, and 96 h. The median lethal concentrations (LC50) at 24 h, 48 h, 72 h, and 96 h were calculated using Probit analysis.

2.3. Experimental Procedures

The reactor used for the treatment was made of glass with the dimensions of 160 × 160 × 250 mm totalizing a volume of 3 L of effluent per treatment (Figure 1). The experiments were performed in a bipolar batch reactor, with two iron electrodes anode (Fe: 99.25% – CT2) and carbon plated iron cathode, dimensions of 146 × 150 × 4 mm connected in parallel. Only the outer electrodes were connected to the digital DC power supply (QJ3003XE, 30V–3A). While the air flow rate was fixed at 3 L/min [30], the electric current applied in the treatments was ranged from 1.11 to 3.33 mA/cm2. For better electron conductivity in the effluent, 990 mg/L of Na2SO4 was added to each treatment. Furthermore, to avoid electrode passivation, at the end of each run, the electrodes were washed thoroughly with water and dipped in 0.5 M H2SO4 solution for at least 15 min to dissolve any oxide from the electrode surface All trials were performed at room temperature of 20 to 25°C (±1.0°C) and adjusted initial pH from 2.8 to 3.2 using H2SO4 (0.2 M) before conducting the experiments.

2.4. Experimental Design

Screening experiments with fixed current density of 2.22 mA/cm2 and 0.2 mM of Fe2+ dosage for 180 min were conducted to determine kinetic reaction and also investigate the effect of these factors on TC and TOC removal efficiency. Then the central composite design (CCD) was then carried out to determine the optimal condition for TOC and TC removal during the EF process. Three independent variables were applied: current density (X1), Fe2+ dosage (X2), and electrolysis time (X3). The level of each code ranged from low (−1) to high (1), as shown in Table 1 based on our previous screening experiments.

Twenty experimental sets were designed, including eight sets from 2 k of a factorial point, six sets from 2 k of the axial point, and six sets from the central point (Table 2), where k is the number of independent variables factors [31]. The TC and TOC removal efficiencies, calculated by the following equation, were defined as the dependent variable’s response.where C0 is the concentration of TC or TOC at the initial time and Ci is the concentration of TC or TOC at any time t of electrolysis.

The mathematics model was evaluated using Minitab version 18.1 software and expressed in a quadratic model equation as follows. The least-square regression calculated the coefficient. The β0, βi, βii, βij, and e are the constant coefficient, linear coefficient, quadratic coefficient, interaction coefficient, and statistical error, respectively. The adequacy and significance of the model were justified by the analysis of variance (ANOVA).

To verify the model accuracy, three confirmed experiments were also conducted at optimal condition (current density of 2.2 mA/cm2, the Fe2+ dosage of 0.25 mM, and electrolysis time of 217 min).

2.5. Analysis Method and Energy Consumption

All assays were performed at room temperature (20 to 25°C), and the treated samples were collected, filtered, and analyzed for total nitrogen (TN) and total organic carbon (TOC), using TOC VCPH/CPN instrument (SHIMADZU, Japan). TC was analyzed by LC-tandem MS equipped with a turbo spray electrospray (ESI) interface (Agilent Technologies, Palo Alto, CA and MS/MS, 4000 QTRAP, Applied Biosystems, USA) according to our previous study [6]. Other parameters such as pH, conductivity, and chemical oxygen demand were evaluated according to the Standard Methods for the Examination of Water and Wastewater [32]. In addition to these parameters, sludge production was also analyzed using the gravimetric method. The statistical analysis was performed using the software Minitab 18.1 version (Minitab Inc., USA).

Energy consumed per contaminated pollutant (E) during the EF process could be determined by the following equation [33]:

The concentration of iron generated in the solution or anode consumption was expressed by the following equation:

where pollutant is TC or TOC, F is Faraday’s constant (96485 Columb/mol), M is the molecular weight of iron (56 g/mol), Z is the number of electron transfer (assumed here ZFe = 2), I is the electric current (A), U is the voltage (V), t is the electrolysis time (min), and V is the treated volume (L).

3. Results and Discussion

3.1. Effect of Electrolysis Time and Kinetic Reaction Model on TOC and TC Removal

Figure 2 shows the variation in the electrolysis time on the TC and TOC removal efficiencies. With the increase in the reaction time from 30 to 150 min, the removal efficiency sharply increases, and with the further increase in the electrolysis time, the removal efficiency reaches a plateau. The increase in the rapid and slow removal of TC and TOC with the rise in the electrolysis time can be explained by the reaction between •OH and TC or TOC in wastewater. At a constant TC or TOC concentration, the increased electrolysis time can accelerate •OH formation, leading to a rapid reaction with the TC or TOC contaminant. However, under saturated Fe2+ conditions (0.2 mM), fixed •OH formation inadequate react with the pollutants; therefore, the TC and TOC removal efficiency slowly increase. This trend also can be confirmed in some previous studies [20, 34]. The kinetics of the TOC and TC removal under fixed conditions (2.22 mA/cm2 of current density and 0.2 mM of Fe2+ dosage) give a better understanding of the relationship between TOC or TC concentrations and electrolysis times. TOC and TC removal is performed under pseudo-first-order kinetics with R2 around 0.923 and 0.993, respectively, as illustrated in Figure 2. These results are the following ones reported by Teymori et al. [20] that show that the pseudo-first-order reaction is suitable for degradation of Malachite green using the EF process or Covinich et al. [26], who indicated the TOC removal of mixed industrial wastewater using Fenton process followed by pseudo-first-order kinetics. The high removal efficiency at about 150 min and the fixed condition of Fe2+ and current density release level of each parameter on CCD design eliminate TC and TOC from RPW.

3.2. Model Fitting and Analysis

The ANOVA results of applying the EF process to the RPW are presented in Table 3, showing significant TC and TOC removal factors according to the CCD design.

Table 3 summarizes the individual and interactive effects and the statistical significance of the test variables on TC and TOC removal. The low values (<0.05) indicate the significant impact of almost all factors on TC and TOC reduction. These should be included in the final model. These statements are also confirmed through the Pareto chart with 95% confidence (Figure S1).

Therefore, the model for predicting the removal of TC and TOC using EF is reconstructed to filter out the nonsignificant factors and predicted models, as expressed by the following equations:

The model F-values of 69.43 and 49.69 for the TC and TOC removal, respectively, indicated that the model is sufficiently significant for the regression analysis between response and variable effects. The fit of the model was verified by determining the regression coefficient (R2). The R2TC and R2TOC values of 0.9842 and 0.9781, respectively, indicated that the models cannot explain only the 1.58–2.19% variation of the mean or that the models exhibit satisfactory adjustment of the quadratic models to the experimental data [35]. Moreover, some investigations revealed that an R2 of greater than 0.70 is considered to be suitable for model fitting [36].

Figure 3 illustrates that the TOC removal increased with electrolysis time and varied with current density or Fe2+ dosage. As seen in Figure 3, the TOC removal could be greater than 80% occurred for conditions current density of 1.11 to 3.50 mA/cm2, Fe2+ concentration of ≥0.18 mM, and electrolysis time of ≥190 min.

Figure 4 describes the interactive effect of current density, electrolysis time, and Fe2+ dosage on TC removal efficiency. The best condition for TC removal by EF was electrolysis time of higher 190 min, current density ranged from 2.0 to 3.0 mA/cm2, and higher Fe2+ dosage of 0.2 mM. The increase in TOC removal efficiency as the Fe2+ concentration ≥ 0.2 mM or increase in electrolysis time could be attributed to the generation of an increased number of ∙OH through equation (1). The variation of removal efficiencies of TC and TOC in a range of current density is mainly due to the suitable range of current density of the experiment. As the current density increase, the amount of generated H2O2 and iron ion also increase, thus increasing ∙OH formation. However, further increase in the current density could accelerate the production of weak oxidative substances (such as HO2 or O2) according to the following equations [6]:

These increase and variations of trends in electrolysis time and current density are consistent with the previous study of Zhang et al. [37]; they stated that the decomposition of 5,000 mg/L of COD from landfill leachate to around 2,500 mg/L only within 30 min and obtained 1,000 mg/L around 75 min.

From the model, the optimization of the EF treatment was reached with the highest removal efficiency of both TC and TOC; the optimization indicated that at 2.2 mA/cm2 of current density, 0.25 mM of Fe2+ concentration, and 217 min of electrolysis time, the TOC and TC removal reached 87.76% and 104.8% with the desirability function value of 0.901 (Figure 5). Two additional experiments were then performed to verify the optimum results. The average TOC and TC removal value obtained through the experiment was 84.24% and 99.23%, respectively, which agreed well with the predicted response value.

In the case of individual optimization for TC and TOC, the best conditions should be 2.2 mA/cm2 of current density, 0.2 mM of Fe2+ concentration and 188 min of electrolysis time or 2.2 mA/cm2 of current density, 0.25 mM of Fe2+ concentration, and 217 min of electrolysis time for elimination of 100% TC and 87.8% TOC as depicted in Figure 6. Two confirmation trials in optimization of TC reach 99.6%, which is better the optimization value of both TC and TOC and closer than the predicted value. The value was chosen for the cost evaluation.

3.3. Toxicity Evaluation

The toxicity of treated real pesticides at optimum condition for both TC and TOC was investigated using D. magna; the survival of D. magna in the controls without pesticide wastewater was 100%. According to OECD guidelines, this high control survival meets the requirement for the toxicity test [28]. The lethal concentration (LC) values of the treated pesticide wastewater (TPW) by EB against the microcrustacean D. magna at different time intervals are listed in Table 4. The results demonstrated that the TPW generated moderate toxic effects on D. magna, with LC50 values of 3.12%, 2.05%, 1.81%, and 1.36% at 24 h, 48 h, 72 h, and 96 h, respectively. These toxicity results are lower than our previous pesticide wastewater on D. magna [6]. However, the pesticide wastewater treatment with this condition still generates toxic effects on D. magna. Probably, the treated pesticide wastewater contained unknown or other toxic compounds that contributed to toxic effects on D. magna. Further study on the chemical composition and toxic effects of this treated wastewater on other aquatic organisms is recommended. The method could require more treatment steps to reach the standard for release to the environment.

3.4. Economic Aspect

One of the most contributions to EF cost is energy consumption, which significantly increases by current density or electrolysis time [18]. The energy consumption for EF treatment was described in equation (4). Given the Vietnamese market in May 2021, the electrical energy price is 0.06 $/kWh, and chemical prices are H2SO4 0.25 $/kg, FeSO4 0.17 $/kg, Na2SO4 0.35 $/kg, and electrode anode 0.33 $/kg (iron). The optimal cost associated with treatment conditions is summarized in Table S1. As shown in Table S1, the operating costs to treat 99.6% TC and 84.2% TOC in RPW using EF were 3.019 $/kg TOC and 121.392 $/kg TC, corresponding to 3.916 $/m3 and 2.962 $/m3 containing 1,297 mg/L TOC and 24.4 mg/L TC, respectively. The high energy consumption in TC removal was mainly due to the low concentration of TC in RPW, which required many chemicals or energy costs for treatment. While the energy consumption to remove 1 kg of TOC in real wastewater is far below the energy consumption of EF reported from previous studies [3842]. Flox et al. [39] indicated an energy consumption cost of around 2.872 $/kg TOC to eliminate 97% TOC of Mecoprop solution using boron-doped diamond (BDD)/stainless steel electrodes. Guinea et al. [42] applied BDD anode to degrade over 97% TOC of enrofloxacin solution with very high energy consumption (14.76 $/kg TOC). A summary list of different contaminant sources degradation by EF along with their treatment efficiency is presented in Table 5. The results indicated that the EF process was suitable for wastewater treatment in a future large-scale application.

4. Conclusions

This study employed the electro-Fenton process with stainless steel and carbon fiber as electrodes to treat tricyclazole (TC) and TOC in real pesticide production wastewater (RPW). The removal of TC and TOC was obeyed pseudo-first-order kinetic with R2 of 0.993 and 0.923, respectively. The central composite design (CCD) with three factors was successfully applied to develop a mathematical model predicting TC and TOC removal. The R2TC = 0.9842 and R2TOC = 0.9781 for the obtained quadratic model indicate a high correlation between observed and predicted values by the mathematical model. At optimum values of variables (current density of 2.2 mA/cm2, Fe2+ dosage of 0.2 mM, and electrolysis time of 217 min), most of the TC (99.6%) and TOC (84.2%) was eliminated. The acute toxicity of this contaminant at optimization conditions still generated toxic effects on D. magna. Besides, the operation cost per mass unit of EF at individual optimization was around 3.019 $/kg TOC and 121.392 $/kg TC also represented the practical technique in wastewater treatment.

Data Availability

All data are included within the article.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Acknowledgments

This research was funded by Vietnam National University Ho Chi Minh City (VNU-HCM) under grant number C2019-24-01.

Supplementary Materials

Table S1. Operation cost for the mineralization of wastewater containing pesticide compounds for EF treatments. Figure S1. Pareto chart for the analysis of the experimental data obtained to remove: (a) TC and (b) TOC from the RPW by EF technique with 95% confidence. (Supplementary Materials)