Research Article
Comprehensive Analysis of ZVS Operation Range and Deadband Conditions of a Dual H-Bridge Bidirectional DC-DC Converter with Phase Shift Control
Table 6
Main proposed circuit parameters.
| Parameter descriptions | Symbol | Value |
| Output voltage | | 28−35 V | Input voltage | | 270 V | Rated power | | 5 kW | Total snubber capacitor | Cds | 0.1 nF | Total DAB inductance | Ls | 460 μH | Transformer turns ratio | n | 9.6 |
|
|