Reference values of model parameters involved in the sensitivity analyses for iFR and FFR under resting and hyperemic conditions.

Model parameterReference value (resting/hyperemic)Range of variation (resting)

EOAdia (cm2)0.0/0.0(0.0∼0.3) [27]
EOAsys (cm2)4.0/4.0(4.0∼1.0) [28, 29]
Elva (mmHg/ml)2.87/2.87(1.435∼6.601) [30]
Elvb (mmHg/ml)0.056/0.056(0.028∼0.112) [30]
HR (beats/min)66/90(48∼111) [31, 32]
aPWV (m/s)4.7/4.7(3.478∼10.011) [3335]
Rsys (mmHg·s/ml)1.14/0.98(0.456∼1.824) [36, 37]
Rcmv (mmHg·s/ml)196.97/45.94(157.58∼433.33) [3840]