Boolean-Based Surface Procedure for the External Heat Transfer Analysis of Dams during Construction
Algorithm 3
Initial detection of the hole surfaces , transverse joint surfaces , and rock-exposed surfaces _rock.
(1)
(2) for do
(3) ((Surface of elements with mono_ID [lift_ID] = ) (those with mono_ID [lift_ID] i + 1))
(4) end loop i
(5) Recognize all external surfaces of elements with mono_ID 0, and noted them as S_base.
// Searching for only the base elements based on Algorithm 2, that means the foundation faces the dam sits upon will
also be included.
(6) S_rock .
We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.