Research Article
Control of Wind-Induced Vibration of Transmission Tower-Line System by Using a Spring Pendulum
Table 1
Conductor line and ground line properties.
| ā | Conductor line | Ground line |
| Type | LGJ-400/35 | LGJ-95/55 | Outside diameter (mm) | 26.82 | 16 | Modulus (GPa) | 65 | 105 | Cross-section (mm2) | 425.24 | 152.81 | Mass per unit length (Kg/m) | 1.3490 | 0.6967 |
|
|