Table 1

System parameters of the paraxial lens design of the 3D sensor system (see Figure 6).

Spectral range projection-imaging Visible

NAProjection 0.019
NAImaging 0.13
Lens diameter projection 5 mm
Lens diameter imaging 6 mm
Magnification projection 0.224
Magnification imaging 11.15
Object field diagonal (projection) 3.564 mm
Measurement field diagonal 0.85 mm
Detection field diagonal (imaging) 8.92 mm
Trinangulation angle 9°
Distance BiMiD-MO (projection path) 160 mm
Detector resolution (imaging) 592 592 Pixel
Active area BiMiD 12.8 mm 9.6 mm

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19.