Research Article

High-Power Laser Cutting of Steel Plates: Heat Affected Zone Analysis

Table 7

Confirmation experiments—MZ.

(W) (mm/min) (mm)Experimental MZModelled MZError%

50006001.52.752.76−0.36
4000220011.401.362.9