Research Article

Pull-Out Resistance Capacity of a New Perfobond Shear Connector for Steel Pile Cap Strengthening

Table 3

Results of the pull-out test.

SpecimenPeak load (kN) Displacement at
peak load (mm)
Cracking load (kN)
Cracking on top of
the concrete block
Vertical cracking on the
side of the concrete block
Horizontal cracking on the
side of the concrete block

PN-0015-N16.61.9515N/AN/A
PO-5015-N97.45.94489797
PO-6015-N99.25.20768894
PO-4015-R78.37.136478N/A
PO-5015-R81.35.21336969
PO-6015-R100.812.0236N/AN/A
PO-5027-N145.612.7385141N/A
PO-5027-R154.714.40130135N/A
PU-5027-N146.137.48118136N/A
PU-5027-R202.226.76148153153