Research Article

Applicability of the Modified Ritchie-Knott-Rice Failure Criterion to Examine the Feasibility of Miniaturized Charpy Type SE(B) Specimens

Table 2

Fracture toughness test results of 10t SE(B) specimens (S55C steel, 20°C). Here, and denote the mean and standard deviation of each parameter, respectively. Though was smaller than 30, cleavage fracture with negligible stable crack extension was observed.

Specimen id 122/%

0.540.540.540
(kN)4.464.254.360.105
(MPam1/2)54.251.652.91.30
(N/mm)79.868.174.05.85
(MPam1/2)1341241295.007.75
(mm)0.130.020.0750.055
22.726.624.71.95