Research Article

Estimation of Concrete Carbonation Depth Considering Multiple Influencing Factors on the Deterioration of Durability for Reinforced Concrete Structures

Table 7

Field investigation data (Building 5, construction completion year: 1983).

Measurement pointMember typeConcrete compressive strength (MPa)Concrete carbonation depth (mm)Cover depth (mm)Crack width (mm)

B5P1Wall25.714.47100
B5P2Wall30.918.3960
B5P3Beam27.912.7455
B5P4Column30.715.3740
B5P5Slab34.08.7725
B5P6Beam30.720.9170
B5P7Column25.89.7650
B5P8Slab34.021.4635
B5P9Beam31.410.1745
B5P10Column28.415.5745
B5P11Slab25.420.0425
B5P12Beam30.617.8245
B5P13Beam27.740.2350
B5P14Slab23.237.2530
B5P15Column31.517.9260
B5P16Beam29.212.8555
B5P17Column25.914.6550Surface finishing crack
B5P18Column32.852.0170Surface finishing crack
B5P19Column27.377.6080
B5P20Beam33.910.1775
B5P21Beam27.618.0150