Table 1

Average measured and simulated magnetic flux density (mT).

Linear distance 2 mm
(simulation)
Linear distance 2 mm
(measurement)
Difference (%)Circular distance 2 mm (simulation)Circular distance 2 mm
(measurement)
Difference (%)

Iron hemisphere0.1850.14825%0.2660.21722%
Spherical magnet0.320.2623%0.420.36315%