Research Article
Evaluation of Parameters Affecting Magnetic Abrasive Finishing on Concave Freeform Surface of Al Alloy via RSM Method
Table 1
Average measured and simulated magnetic flux density (mT).
| | Linear distance 2 mm (simulation) | Linear distance 2 mm (measurement) | Difference (%) | Circular distance 2 mm (simulation) | Circular distance 2 mm (measurement) | Difference (%) |
| Iron hemisphere | 0.185 | 0.148 | 25% | 0.266 | 0.217 | 22% | Spherical magnet | 0.32 | 0.26 | 23% | 0.42 | 0.363 | 15% |
|
|