Stiffness-Displacement Correlation from the RC Shear Wall Tests of the SAFE Program: Derivation of a Capacity Line Model
Table 2
Parameters of tested walls II.
Specimen
(actual)
MPa
MPa
MPa
mrad
mm
m/s2
Wall T01
0
0.37
4.00
0.281
0.337
Wall T02
0
0.37
4.00
0.281
0.337
Wall T03
0
0.37
4.00
0.281
0.337
2.55
0.083
Wall T04
0
0.37
4.00
0.281
0.337
1.49
1.286
Wall T05
0
0.32
4.00
0.281
0.337
2.01
0.424
Wall T06
1
1.01
3.00
0.211
0.253
1.49
0.965
Wall T07
1
1.01
3.00
0.211
0.253
2.55
0.063
Wall T08
0
0.32
2.00
0.140
0.169
1.49
0.643
Wall T09
0
0.32
2.00
0.140
0.169
2.55
0.042
Wall T10
0
0.32
3.00
0.211
0.253
2.55
0.063
Wall T11
0
0.32
2.00
0.140
0.169
2.55
0.042
Wall T12
1
1.01
1.55
0.109
0.131
2.55
0.032
Wall T13
0
0.32
2.00
0.140
0.169
1.49
0.643
The tests on walls T01 and T02 did not follow the same design scheme as the rest of the walls and their results will be used in this study only in a limited manner.