Research Article

Stiffness-Displacement Correlation from the RC Shear Wall Tests of the SAFE Program: Derivation of a Capacity Line Model

Table 2

Parameters of tested walls II.

Specimen (actual)
MPaMPaMPamradmmm/s2

Wall T0100.374.000.2810.337
Wall T0200.374.000.2810.337
Wall T0300.374.000.2810.3372.550.083
Wall T0400.374.000.2810.3371.491.286
Wall T0500.324.000.2810.3372.010.424
Wall T0611.013.000.2110.2531.490.965
Wall T0711.013.000.2110.2532.550.063
Wall T0800.322.000.1400.1691.490.643
Wall T0900.322.000.1400.1692.550.042
Wall T1000.323.000.2110.2532.550.063
Wall T1100.322.000.1400.1692.550.042
Wall T1211.011.550.1090.1312.550.032
Wall T1300.322.000.1400.1691.490.643

The tests on walls T01 and T02 did not follow the same design scheme as the rest of the walls and their results will be used in this study only in a limited manner.