Research Article

Study on the Formation Law of the Freezing Temperature Field of Freezing Shaft Sinking under the Action of Large-Flow-Rate Groundwater

Table 4

Freezing parameters of wind well in Zhangji Mine.

ParametersValueUnit

Inner diameter of the wellbore7m
Diameter of the excavation boundary9m
Auxiliary freezing pipeDiameter of the arrangement area13m
Quantity181
Spacing2.27m
Temperature−32°C
Size of freezing pipe159 × 6mm
Main freezing pipeDiameter of the arrangement area17m
Quantity421
Spacing1.27m
Temperature−32°C
Size of freezing pipe159 × 6mm
Row spacing2m