Research Article

Thermomechanical Optimization and Comparison of a Low Thermal Inertia Mold with Rectangular Heating Channels and a Conventional Mold

Table 8

Thermomechanical results for optimal mold designs.

Prediction RSMVerification FEMError (%)

Circular optimizedWatertheating (s)442.54723.1
ΔT (°C)1.941.890.6
umax (μm)3.994.038.5
Oiltheating (s)8587990.8
ΔT (°C)0.720.453.0
umax (μm)4.244.514.6

Rectangular optimizedWatertheating (s)3953881.7
ΔT (°C)0.620.640.1
umax (μm)9.986.729.9
Oiltheating (s)372.44302.2
ΔT (°C)0.230.461
umax (μm)10.838.739.7