Research Article

Mechanical Recovery of Cracked Fiber-Reinforced Mortar Incorporating Crystalline Admixture, Expansive Agent, and Geomaterial

Table 5

Water flow rate and self-healing indices of the three mixes.

Mix typeCrack width (μm)Water flow (ml·mm−1·min−1)Self-healing index (%)

OPC-28D-2272270.680.1972.4
OPC-28D-2412410.890.3066.0
OPC-28D-2502501.060.4063.0
SH1-28D-2212210.750.1284.3
SH1-28D-2302300.900.1682.2
SH1-28D-2472471.000.1881.9
SH2-28D-2252250.740.0691.9
SH2-28D-2382380.810.0989.3
SH2-28D-2512511.010.1188.7