Research Article

Study on the Relationship between Mechanical Properties and Mesostructure of Microbial Cemented Sand Bodies

Table 2

Orthogonal design test condition.

IDTest factor
Bacterial concentration (Mb)Bacterial fluid flow (Qb) (ml/min)Bacterial solution standing time (Tb) (h)Cement concentration (Mc) (mol/L)Cement flow(Qc) (ml/min)Cementation standing time (Tc) (h)

1#0.25110.2511
2#0.25330.5033
3#0.25550.7555
4#0.251081.00108
5#0.2515121.501512
6#0.50130.751012
7#0.50351.00151
8#0.50581.5013
9#0.5010120.2535
10#0.501510.5058
11#1.0151.5038
12#1.0380.25512
13#1.05120.50101
14#1.01010.75153
15#1.01531.0015
16#1.5180.50155
17#1.53120.7518
18#1.5511.00312
19#1.51031.5051
20#1.51550.25103
21#2.01121.0053
22#2.0311.50105
23#2.0530.25158
24#2.01050.50112
25#2.01580.7531