Research Article

Simultaneous Determination of Amlodipine, Hydrochlorothiazide, and Valsartan in Pharmaceutical Products by a Combination of Full Spectrum Measurement and Kalman Filter Algorithm

Table 7

Measured concentrations of AML, HYD, and VAL in Exforge HCT tablets employing the developed Kalman-Excel program.

Replicate samplesAMLHYDVAL
CAML (mg/mL)Mass per tablet (mg)CHYD (mg/mL)Mass per tablet (mg)CVAL (mg/mL)Mass per tablet (mg)

B10.9659.651.16811.6816.997169.97
B20.9809.801.18611.8617.249172.49
B30.9379.371.13411.3416.506165.06
Cmean (mg/mL)0.9619.611.16311.63016.917169.170
S0.0220.220.0260.260.3783.78
RSD %2.32.32.22.22.22.2
1/2 RSDHorwitz (%)85.55.3