Research Article

Corrosion Resistance of DLC Film-Coated SUS316L Steel Prepared by Ion Beam Enhanced Deposition

Table 4

Metal ion concentration for the bare and DLC film-coated SUS316L after 168 h corrosion.

SubstrateCH4/H2 = 1 : 1CH4/H2 = 1 : 1CH4/H2 = 1 : 0CH4/H2 = 1 : 0
6 h12 h6 h12 h

ICP (ppm)51.7216.6025.2219.5633.90