Abstract

To economically and reasonably solve the difficult problem of mine shaft support subject to complex geological conditions, we studied the mechanical properties of polypropylene macrofiber-reinforced concrete (PPMFRC). First, we selected test raw materials through an investigation and comparison of technical parameters. Second, using a preparation test, we obtained the composition of reference concrete of PPMFRC for the mine shaft lining structure, and test specimens were manufactured according to relevant test technical regulations. Finally, the mechanical properties of the specimens were compared, and the results show that the compressive, flexural, and tensile strengths of PPMFRC were increased by approximately 3%, 30%, and 20%, respectively, for mixtures with polypropylene macrofibers. The fracture toughness of PPMFRC was between 0.26 and 0.35, and the fracture energy was between 382.7 N/m and 485.6 N/m, which is significantly higher than that of plain concrete. The test results show that PPMFRC is an ideal material for the lining structure of a mine shaft under complex geological conditions, and we have provided technical parameters for engineering applications.

1. Introduction

To exploit deep underground mineral resources, vertical shafts must be constructed in the stratum to transport minerals, personnel, materials, equipment, ventilation, etc. A wellbore maintains stability because of a shaft lining structure close to its inner wall. In the past, plain concrete was primarily used for the lining. However, with the increase of mining depth, the engineering geological and hydrological conditions of the strata through which the wellbore passed became more complex. Meanwhile, the concrete used in the shaft lining was subjected to compressive stress, tensile stress, etc. Hence, the concrete cracked easily. Further, when subjected to underground pressure water, the cracks caused fracture and expansion, which seriously affected the safe use of the shaft. Thus, concrete for deep shaft lining required not only high compressive strength, but also high tensile strength, flexural strength, crack resistance, and permeability resistance. A few scholars developed shaft lining structures made of steel fiber and steel skeleton-reinforced concrete, and these new types of reinforced concrete were successfully applied to engineering practices [14]. Nevertheless, through engineering applications, they were considered expensive and easily corroded. Therefore, it is necessary to find a new material for the shaft lining structure.

Polypropylene macrofiber is a fiber with diameter and length exceeding 0.1 and 40 mm, respectively, and it is developed from polypropylene and polyethylene, which are the main raw materials. When the polypropylene macrofibers in concrete reach a certain level, they behave in a manner similar to steel fibers. Thus, the fibers are also referred to as “imitation steel fibers” [57]. Polypropylene macrofibers have many advantages such as high tensile strength, corrosion resistance, good chemical stability, strong bonding strength with concrete, and easy construction. However, few researchers have investigated the application of polypropylene macrofiber-reinforced concrete (PPMFRC) to underground structures. To economically and feasibly solve the difficult supporting problems of mine shaft lining structures under complex conditions, PPMFRC was prepared and its mechanical properties were studied.

2. Materials and Preparation

2.1. Materials
2.1.1. Cement

In this study, Conch P.II 52.5 Portland cement, with the specific surface area 389 m2/kg, was selected. Its initial and final setting times were 145 and 199 min, respectively, and the cement was qualified as stable. Its 3 d compressive and flexural strengths were 25.7 and 4.6 MPa, respectively, and its 28 d compressive strength and flexural strength were 55.8 and 7.3 MPa, respectively.

2.1.2. Aggregate

Sand from Huaihe River was selected as the fine aggregate with a fineness module of 2.9 and saturated surface drying density of 2580 kg/m3. Basalt gravel was selected as the coarse aggregate with a particle size of less than 25 mm and saturated surface drying density of 2720 kg/m3.

2.1.3. Plasticizer

This study used the high-performance water-reducing agent NF produced by Anhui Huaihe Chemical Co., Ltd.; its water reducing rate is greater than 30%.

2.1.4. Admixture

Furthermore, this study used slag, with a specific surface area greater than 350 m2/kg, produced by Anhui Hefei Qingya Building Material Co., Ltd. The microsilicon powder produced by Shanxi Dongyi Ferroalloy Factory was selected. Its specific surface area was greater than 18000 m2/kg.

2.1.5. Fiber

The polypropylene macrofiber produced by Hangzhou Jianqing Fiber Company was selected (Figure 1). The parameters of the fiber are listed in Table 1.

2.2. Mixture Composition and Preparation

Existing studies have generally used concrete with a standard cubic compressive strength of 60 MPa (C60) for shaft lining structures, and thus, C60 was taken as the design value of concrete strength in this test. The composition of the reference concrete for the test was then obtained from an orthogonal test (Table 2).

Four groups of specimens were needed for each test. One group comprised plain concrete specimens; these were considered to be reference concrete. The other three groups were PPMFRC specimens containing 0.5%, 1.0%, and 1.5% (volume fraction) fibers. The four groups were named A-0, A-0.5, A-1.0, and A-1.5, respectively. Each group had three specimens whose shapes and sizes corresponding to each test are shown in Figure 2.

The sequence for mixing the PPMFRC was as follows. First, cement, aggregate, and admixture were dry-mixed in a concrete mixer for 2 min. Second, polypropylene macrofibers were added and the mixture was stirred for 2 min. Then, NF water reducer was dissolved in 60% water and poured into the mixer for 3 min. Finally, the remaining 40% of the water was poured into the mixer and stirred for 3 min.

Specimens were poured and vibrated onanHZJ-0.8 concrete shaking table until slurry was discharged. After shaping, the surface was immediately covered with impervious film and the specimens in molds were placed in an ambient temperature of 20°C for 24 h. Then, the specimens were demolded and placed in a YH-40 standard curing box (20 ± 2°C, 95% humidity) for 28 d.

2.3. Experimental Methods and Facilities

In the experiment, the WAW2000B universal testing machine developed by SFMIT was used, and the load and displacement were recorded using the Test Master software [8, 9]. After all specimens were removed from the standard maintenance box, they were wiped clean with a dry cloth, and then they were placed in the dry equipment and corrected according to the specifications. An anticracking net cover was installed around the test machine to ensure safety.

In the compressive strength test, loading rate was controlled between 0.08 and 0.10 MPa/s. When the specimen was close to failure and began to deform sharply, we stopped adjusting the throttle of the testing machine until failure occurred.

In the flexural strength test, the loading rate was controlled between 0.08 and 0.10 MPa/s. Using the flexural test device, two equal loads were simultaneously applied at three points of the specimen span. The loading diagram is shown in Figure 3.

In the uniaxial tensile test, a pair of special fixtures (Figure 4) matching the size of the test specimen were used, and the loading rate was controlled at 1.2 mm/min. To reduce the effects of eccentric load, the articulated ring was welded to the outer end of the upper fixture and greased to improve articulation effects.

In the wedged split tensile test, the loading rate was controlled at 0.3 mm/min using a step-by-step continuous loading method. The splitting and pulling device (Figure 5) was clamped into the wide slot cut in advance in to the specimen. The clamp extensometer was installed to monitor the V value of the crack. The time from the beginning of loading to fracturing of specimens was 30–50 min. When the specimen approached failure, the loading speed was reduced and the test process was maintained at as table level. Finally, the F-V curve for the test was obtained.

In the bending test, a 20 mm crack was cut into the center of the lower surface for specimen. The loading speed was controlled at 0.025 mm/min, and a clamp extensometer was installed to monitor the crack deflection. When the material approached failure, the loading speed was reduced appropriately. Finally, the F-δ curve (load-deflection curve) for the three-point bending notched beam was obtained.

3. Results and Discussion

3.1. Compressive Strength Test

Vertical load was recorded using Test Master measurement and control software, and the peak values were labeled. The numerical values were accurate to 0.1 MPa. Normally, the average value of three specimens is taken as the strength value of the group of specimens. However, if the difference between the maximum value and the minimum value of the three measurements exceeds 15% of the median value, the maximum value and the minimum value are discarded, and the median value is taken as the compressive strength value of the group of specimens. If the difference between the maximum and the median value and the minimum and the median value exceeds 15% of the median values, the test results for the specimen group are invalid. The test results are listed in Table 3.

Table 3 shows that the compressive strength of PPMFRC increased with increasing fiber ratios. For fiber ratios of 1.0% and 1.5%, the strength increased by 3.4%. It shows that the addition of polypropylene macrofibers improves the compressive strength of concrete; however, the range is limited. The best volume ratio to improve the compressive strength of PPMFRC can be selected as 1.0%.

3.2. Flexural Strength Test

Flexural strength was calculated from peak load. Because the specimen sizes were nonstandard, the flexural strength results had to be converted (formula 1). The numerical value was accurate to 0.1 MPa. The strength determination method was the same as that in compressive strength testing. The test results are listed in Table 4:where ff is the flexural strength (MPa), 0.85 is the dimension conversion coefficient, Fzmax is the peak load (kN), l is the span between supports (mm), h is the section height (mm), and b is the section weight (mm).

Figure 6 shows that before the ultimate flexural strength of plain concrete was reached, the curves basically coincided and linearity was evident. Then, different curves began to show different trends. After reaching the peak value, the stress of plain concrete decreased rapidly. Although the concrete had residual strength, it was completely destroyed in a short time and brittle failure was very evident. Over time, PPMFRC materials with different fiber dosages continued to bear loads. PPMFRC reached its ultimate strength and was destroyed at 210 s, which was nearly 30 s longer than the duration for plain concrete. Additionally, the decline rate of PPMFRC was slower than that of plain concrete. When the fiber content was 1.0%, PPMFRC had the highest flexural strength. Therefore, 1.0% can be used as the best volume fraction for flexural strength.

3.3. Uniaxial Tensile Strength Test

We found that most of the fibers were pulled out of the material. Meanwhile, a few fibers were not pulled out; however, they were instead broken because of the strong bond between the fibers and the concrete matrix. When the concrete cracked, the bonding force between the fibers and the concrete matrix played a key role. Then, most of the fibers were pulled out. However, a few fibers having a high bonding force with the concrete matrix were not pulled out, and their tensile strength resisted overall fracturing.

Because of the randomness of the distribution of coarse aggregate and fibers in the concrete, the distribution of original defects such as cracks and voids in the concrete was also random (Figure 7). The internal randomness caused the strength and stress distributions to different in various sections of specimens; thus, no evident specimen failure was observed. The fracture surfaces for some specimens were near the middle of the specimens. However, the fracture surfaces for the other specimens were only approximately 110–140 mm away from the clamp opening.

During testing, a few specimens cracked on the one side, and then on the other side, the cracks eventually expand to the interior and break through. Most of the specimens cracked initially on one side, with the cracks gradually expanding to the interior and ultimately penetrating the damage. This phenomenon was mainly owing to a certain degree of eccentric tension after the first initial cracking in most specimens, which resulted in the crack extending inward along one side.

Table 5 shows that, with increase in fiber content, both the ultimate tensile strength and peak strain increased. When the dosage was 1.5%, the ultimate tensile strength was 21.4% higher than that of plain concrete. In the stage prior to the 70–80% peak values, the stress-strain relationship was linear elastic. In this stage, the microcracks were relatively smaller and their influence was weak. With increasing stress, microcracks gradually began to expand, which affected the stress area of the specimen, making residual stress increase and further increasing failure trends.

3.4. Wedged Split Tensile Test

Draw F-V curve (vertical load-displacement of crack opening curve) (Figure 8) and calculate initial fracture toughness , instability fracture toughness , effective crack length ac, fracture energy Gf, and tensile strength f:where FHQ is the horizontal load of initial fracture (kN), FHS is the horizontal load of instability fracture (kN), t is the ligament thickness (mm), h is the ligament height (mm), h0 is the thickness of cutter edge thin steel plate of clamp extension meter (mm), a0is the initial length of crack (mm), E is the modulus of elasticity (GPa), ci = Vi/Fi, is the reciprocal slope of straight line segment in curve ascent (mm/kN), , Vc is the critical value of crack opening displacement (mm), W is the work done by vertical load, envelope area of F-V curve (J), and y is the distance from the ligament center to the horizontal loading point (mm) [10]. The test and calculation results are listed in Table 6.

The failure modes of concrete can be clearly observed from Figure 9. The matrix of plain concrete is completely split and divided into two parts. The brittle failure mode is evident. Under the same stress, PPMFRC with 1.5% fiber content exhibits microcracks but no evident damage, and the effects of fiber crack prevention are evident.

3.5. Bending Test

According to the load, deflection, and crack opening displacement measured by the test, F-δ curve (vertical load-deflection) is drawn, and the fracture toughness KIC and fracture energy Gf are calculated:where is the shape factor, Mmax is the sum of the maximum load and the bending moment produced by the deadweight of the beam (N/m), a0 is the notch depth (mm), A0 is the envelope area of Fδ curve (mm2), mg is the deadweight of support section of concrete beam (kN), δmax is the deformation of beams at final failure (mm), and Alig is the ligament area (mm2). The meaning of other parameters is consistent with that of the penetration splitting test. The test and calculation results are listed in Table 7.

Figure 10 shows that there are only two stages in plain concrete: elastic and failure stages. The brittle failure characteristics are evident. PPMFRC has evident elastic-plastic characteristics, which can be divided into the elastic, deflection stable development, deflection instability, and failure stages. In the elastic stage, the curve is linear and the fibers and concrete bear the load together. In the stable development stage of deflection, when the ultimate load reaches 70–80%, the curve slows, the matrix cracks begin to propagate slowly, and the fibers across the cracks begin to play a role in delaying the crack propagation speed until it reaches a peak value. Macroscopic cracks begin to appear near the peak load. In the deflection instability stage, after reaching peak stress, the curve is steep, because the specimen reaches its ultimate strength and destructs. The bearing capacity decreases sharply; however, the deflection changes little. In the damage stage, the fibers show strong crack resistance, with little change in the bearing capacity of the specimens. The deflection continues to develop until the specimens are destroyed, reflecting the high toughness of PPMFRC.

With increasing fiber content, the ultimate strength loads and peak deflection increase. The fiber volume fraction has an evident effect on bending resistance, and fracture energy also increases. The value is between 382.7 and 485.6 N/m. This occurs mainly because the fibers connect the cracks and span between them. When the microcracks expand, the fibers effectively alleviate the stress concentrations of the cracks and prevent the cracks from expanding. The numerical results show that the fracture energy is significantly increased. In addition to overcoming the resistance of the concrete matrix itself, the external load also must overcome the bond stress between the fibers and the matrix, as well as the tensile strength of the fibers themselves.

4. Conclusion

(1)The flexural strength, tensile strength, fracture toughness, and fracture energy of PPMFRC were evidently higher than those of plain concrete. However, the compressive strength of PPMFRC was only slightly higher than that of plain concrete.(2)For a fiber content of 1.0%, the flexural strength of PPMFRC was 29.3% higher than that of plain concrete. With increase in fiber content, the uniaxial tensile strength and wedged split tensile strength of PPMFRC were improved. At a fiber content of 1.5%, the uniaxial tensile strength was highest, and it was 21.4% higher than that of plain concrete.(3)With increasing fiber content, the fracture energy of PPMFRC was improved. When the fiber content was 0.5–1.5%, the fracture toughness of PPMFRC was 0.26–0.35 and the fracture energy was 382.7–485.6 N/m. Thus, the crack resistance of the PPMFRC is evidently better than that of plain concrete.(4)Both the F-V and F-δ curves exhibited the brittleness characteristics of plain concrete and the elastic-plastic characteristics of PPMFRC, and they indicated the evident anticracking and toughening effects of the fibers.

Data Availability

The data used to support the findings of this study are included within the article.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Acknowledgments

This study was supported by the National Natural Science Foundation of China (no. 51674006), Anhui Province University Disciplines (Professional) Top-Notch Talent-Funded Projects (gxbjZD09), Anhui Provincial Natural Science Foundation Youth Project (1908085QE185), Anhui Provincial College of Natural Science Research Key Project (KJ2018A0098), project funded by China Postdoctoral Science Foundation (2018M642502), and Science Research Foundation for Young Teachers in Anhui University of Science and Technology (QN2017211).