Research Article

Experimental Research on Mechanical Property and Environmental Safety of an Industrial Residue Waste Subgrade Material

Table 2

Results of resilient modulus test.

CD1 (%)Resilient modulus (MPa)
Value 1Value 2Value 3Average/SD

100133.56136.42137.63135.87/2.09
96121.34124.48126.82124.21/2.75

1CD = compaction degree. 2SD = standard deviation.