Research Article

Optimal Design of the Sealing Structure of a Hydraulic Cylinder on the Basis of a Surrogate Model

Table 5

Reliability of 5 sealed structure joints.

Serial numberShortly after sealing10 years20 years25 years30 years

10.9760.9210.8510.8270.796
20.9830.9260.8460.8210.793
30.9840.9270.8590.8350.794
40.9870.9310.8610.8450.807
50.9940.9380.8810.8480.813