Research Article

A Study of Impact Response and Its Numerical Study of Hybrid Polypropylene Fiber-Reinforced Concrete with Different Sizes

Table 6

The fitting value of parameters a and b under different fiber hybridizations.

Impact load (sāˆ’1)Parameters a and bA3A4A5A6

32.30.00290.00240.00330.0025
1.2241.1611.4231.391
65.30.00210.00580.00340.0042
1.2251.3011.1931.138
80.50.00230.00490.00190.0018
1.0261.3251.1420.94
92.70.00280.00320.00240.0036
1.2821.2380.8791.172
106.30.00230.00370.00220.003
1.0241.0360.9091.079