Performance experiment of logarithmic spiral method.

Measured valuen = 2900 (r/min)
Inlet pressureOutlet pressureQnPinQHPinη
(kPa)(kPa)(m3/h)(r/min)(kW)(m3/h)(m)(kW)(%)

1−70.00180.0021.332998.605.5820.6326.755.0529.79
2−80.00190.0021.082998.075.3620.3928.624.8532.77
3−80.00210.0020.243001.455.2119.5630.304.7034.35
4−80.00230.0018.983002.295.2018.3331.954.6934.05
5−60.00250.0016.503001.645.0115.9431.554.5233.32
6−50.00280.0014.653001.624.8014.1533.184.3329.55
7−30.00310.0011.303001.654.4810.9233.724.0424.82
8−30.00320.001.543001.624.4210.1834.593.9924.08
9−20.00330.008.463001.774.208.1734.403.7920.23
10−20.00340.007.353001.724.117.1035.273.7118.41
11−20.00340.005.933001.503.985.7335.193.5915.30
12−10.00350.002.633001.253.742.5435.063.377.19
13−10.00370.000.003001.343.430.0036.933.090.00