Research Article

Surface and New Building Deformation Analysis of Deep Well Strip Mining

Table 4

Numerical stimulation results in different mining length.

Mining length (m)Maximum subsidence value (m)Subsidence factorRemark

4000.5610.02Mining depth 1000 m, mining thickness 8 m, mining width 80 m, leaving width 100 m
6000.8760.06
8000.7190.09
10001.1970.13