Research Article

Study on the Heat of Hydration and Strength Development of Cast-In-Situ Foamed Concrete

Table 2

Details of the projects.

ProjectDesign casting density (kg/m3)Measured casting density (kg/m3)Mix proportions (/m3)Construction locationWeather

110001018.5, 1011.1C : F : W : A = 640 : 0:346 : 448Zigong city, Sichuan provinceWind speed: 1–3
Humidity: 78–80%
2650651.4, 656.7, 654.2C : F : W : A = 405 : 0:223 : 647Chengdu city, Sichuan provinceWind speed: 1–3
Humidity: 83–86%
3670657.8, 663.5, 675.6C : F : W : A = 420 : 0:231 : 634Huai’an city, Jiangsu provinceWind speed: 1–3
Humidity: 69–71%
4700702.1, 721.5, 694.8C : F : W : A = 308 : 132 : 246 : 602Guiyang city, Guizhou provinceWind speed: 0–4
Humidity: 61–81%

Note: C : F : W : A = cement (kg) : fly ash (kg) : water (kg) : air bubbles (l).