Research Article

Effect of Combining Fiber and Textile Reinforcement on the Flexural Behavior of UHPC Plates

Table 6

Key values from the crack evaluation.

Specimen typesFirst crack appears (kN)Largest crack reaches 0.1  mm (kN)Largest/mean crack width at 5  kN (mm)Largest crack width at the ultimate load (mm)

UHPFRC3.06.00.05/0.020.3
UHPC + glass textile2.72.71.7
UHPC + carbon textile2.82.81.1/0.701.3
UHPFRC + glass textile2.13.40.34/0.201.3
UHPFRC + carbon Textile1.83.80.18/0.100.9