Research Article
Using Infrared Radiation in a Radiant Wall Oven for Blanching Small-Sized Peanuts
Table 4
Blanching results (%) for the treatment combinations used in this study.
| Treatment | Blanched whole | Blanched split | Unblanched | Total blanched |
| Low moisture control | 62.91 ± 6.51 | 21.62 ± 3.30 | 15.47 ± 5.46 | 84.53 ± 5.46 | Low moisture IR1 | 63.91 ± 3.01 | 23.99 ± 2.57 | 12.09 ± 2.59 | 87.91 ± 2.59 | Low moisture IR2 | 65.22 ± 3.52 | 22.20 ± 6.16 | 12.59 ± 3.10 | 87.41 ± 3.10 |
| High moisture control | 58.79 ± 14.35 | 20.84 ± 3.56 | 20.37 ± 13.02 | 79.63 ± 13.02 | High moisture IR1 | 55.69 ± 12.44 | 19.08 ± 4.40 | 25.24 ± 9.96 | 74.76 ± 9.96 | High moisture IR2 | 57.87 ± 13.46 | 22.93 ± 3.70 | 19.20 ± 10.80 | 80.80 ± 10.80 |
|
|
No significant differences found within the two moisture categories at = 0.05. |