Research Article

The Efficacy of Treated Water from Water Filtration Machines for Safe Drinking Water Supply in Bandar Baru Bangi and Kajang, Selangor

Table 2

The mineral content for 15 samples of treated water.

SampleMineral content (mg/L)
Copper (Cu)Magnesium (Mg)Aluminium (Al)Arsenic (As)Iron (Fe)Zinc (Zn)Lead (Pb)Chromium (Cr)Cadmium (Cd)

A0.0003 ± 0.001.1659 ± 0.010.0065 ± 0.000.0016 ± 0.000.0414 ± 0.000.0034 ± 0.00ND0.0020 ± 0.00ND
B0.0008 ± 0.000.8322 ± 0.040.0025 ± 0.000.0008 ± 0.000.0225 ± 0.000.0057 ± 0.00ND0.0002 ± 0.00ND
C0.0048 ± 0.000.8361 ± 0.020.0061 ± 0.000.0008 ± 0.000.0225 ± 0.000.0848 ± 0.00ND0.0006 ± 0.00ND
D0.0004 ± 0.000.9609 ± 0.020.0103 ± 0.000.0009 ± 0.000.0284 ± 0.000.0334 ± 0.00ND0.0003 ± 0.00ND
E0.0003 ± 0.000.2886 ± 0.000.0053 ± 0.000.0003 ± 0.000.0145 ± 0.000.0154 ± 0.00ND0.0007 ± 0.00ND
F0.0003 ± 0.000.7490 ± 0.030.0061 ± 0.000.0005 ± 0.000.0277 ± 0.000.0119 ± 0.00ND0.0004 ± 0.00ND
G0.0003 ± 0.000.3935 ± 0.020.0099 ± 0.000.0004 ± 0.000.0199 ± 0.000.0071 ± 0.00ND0.0006 ± 0.00ND
H0.0013 ± 0.000.2390 ± 0.010.0091 ± 0.000.0002 ± 0.000.0145 ± 0.000.0058 ± 0.00ND0.0003 ± 0.00ND
I0.0028 ± 0.000.3313 ± 0.010.0106 ± 0.000.0003 ± 0.000.0155 ± 0.000.0076 ± 0.00ND0.0002 ± 0.00ND
J0.0005 ± 0.001.0925 ± 0.010.0059 ± 0.000.0011 ± 0.000.0380 ± 0.000.0125 ± 0.00ND0.0010 ± 0.00ND
K0.0003 ± 0.001.2155 ± 0.050.0109 ± 0.000.0009 ± 0.000.0373 ± 0.000.0060 ± 0.00ND0.0006 ± 0.00ND
L0.0005 ± 0.001.0836 ± 0.030.0059 ± 0.000.0008 ± 0.000.0353 ± 0.000.0254 ± 0.00ND0.0005 ± 0.00ND
M0.0011 ± 0.001.0694 ± 0.050.0182 ± 0.000.0007 ± 0.000.0329 ± 0.000.0281 ± 0.00ND0.0003 ± 0.00ND
N0.0005 ± 0.000.2101 ± 0.000.0061 ± 0.000.0002 ± 0.000.1086 ± 0.000.0217 ± 0.00ND0.0002 ± 0.00ND
O0.0003 ± 0.000.2200 ± 0.000.0090 ± 0.000.0003 ± 0.000.0114 ± 0.000.0207 ± 0.00ND0.0002 ± 0.00ND

ND—not detected. All results are expressed in mean ± SD in triplicates (n = 3).