Research Article

Removal of Pb (II) from Synthetic Solution and Paint Industry Wastewater Using Activated Carbon Derived from African Arrowroot (Canna indica) Stem

Table 4

Paint industry wastewater (untreated and treated) characteristics.

ParametersUnitUntreated wastewaterTreated wastewaterMaximum limited value (WHO, 2017)

pHpH unit5.36.56.5–9.2
Temperature°C20.62040
TurbidityNUT25510
BOD5mg/L1712540
CODmg/L2402150120
TSSmg/L61913845
Pb (II)mg/L4.60.4280.1
Cu (II)mg/L30.2681